INHP-Eco Series
INHP-Eco Series
Various specifications lineup
◆This adopts both the patented energy-saving operation technology that reduces raw material air according to product gas consumption and controls the number of units that controls multiple PSA units!
◆Installed an energy-saving operation mode that reduces raw air while maintaining purity by switching the number of operating units and desorption time depending on the amount generated, and can be easily set with the touch panel.
◆Also supports Chinese, Korean and English as standard feature.
◆Space-saving design with high discharge pressure, low noise and low height.
◆Highly durable and long maintenance cycle! [Approax 2 years (=20,000 hours)]
Parts number/Specifications
Parts number | Nitrogen generation volume (Nm3/h) 0.69 (0.83) MPa |
Purity(%) | Discharge pressure (MPa) 0.69 (0.83) MPa |
Material air volume 0.69 (0.83) MPa |
Appropriate compressor (kw) |
Dimensions (mm) |
Weight(kg) | Sound leveldB(A) |
---|---|---|---|---|---|---|---|---|
INHP5-048Eco | 4.8 (5.6) |
99.999 | 0.6 (0.7) |
0.70 (0.83) |
5.5 | W:720 × D:870 × H:1,380 |
380 | 60 |
INHP4-080Eco | 8.0 (9.4) |
99.99 | ||||||
INHP3-112Eco | 11.2 (13.2) |
99.9 | 0.76 (0.90) |
|||||
INHP2-160Eco | 16.0 (18.8) |
99 | 0.55 (0.65) |
0.80 (0.95) |
||||
INHP5-060Eco | 6.0 (7.0) |
99.999 | 0.6 (0.7) |
0.88 (1.04) |
7.5 | W:720 × D:870 × H:1,380 |
400 | 60 |
INHP4-100Eco | 10.0 (11.8) |
99.99 | ||||||
INHP3-140Eco | 14.0 (16.5) |
99.9 | 0.95 (1.12) |
|||||
INHP2-200Eco | 20.0 (23.5) |
99 | 0.55 (0.65) |
1.00 (1.18) |
||||
INHP5-090Eco | 9.0 (10.6) |
99.999 | 0.6 (0.7) |
1.32 (1.56) |
11 | W:960 × D:870 × H:1,380 |
540 | 60 |
INHP4-150Eco | 15.0 (17.6) |
99.99 | ||||||
INHP3-210Eco | 21.0 (24.7) |
99.9 | 1.43 (1.69) |
|||||
INHP2-300Eco | 30.0 (35.0) |
99 | 0.55 (0.65) |
1.50 (1.77) |
||||
INHP5-120Eco |
12.0 (14.1) |
99.999 | 0.6 (0.7) |
1.75 (2.06) |
11 | W:1,200 × D:870 × H:1,380 |
680 | 60 |
INHP4-200Eco | 20.0 (23.5) |
99.99 | ||||||
INHP3-280Eco | 28.0 (33.0) |
99.9 | 1.90 (2.24) |
15 | ||||
INHP2-400Eco | 40.0 (47.0) |
99 | 0.55 (0.65) |
2.00 (2.36) |
||||
INHP5-180Eco | 18.0 (21.2) |
99.999 | 0.6 (0.7) |
2.65 (3.12) |
22 | W:1,440 × D:870 × H:1,600 |
860 | 60 |
INHP4-300Eco | 30.0 (35.3) |
99.99 | ||||||
INHP3-420Eco | 42.0 (49.4) |
99.9 | 2.86 (3.38) |
|||||
INHP2-600Eco | 60.0 (70.6) |
99 | 0.55 (0.65) |
3.00(3.53) |
||||
INHP5-220Eco |
22.0 (23.5) |
99.999 | 0.6 (0.7) |
3.42 (4.03) |
22 | W:1,680 × D:870 × H:1,650 |
1,050 | 60 |
INHP4-380Eco | 38.0 (44.7) |
99.99 | ||||||
INHP3-530Eco | 53.0 (62.4) |
99.9 | 3.66 (4.31) |
|||||
INHP2-760Eco | 76.0 (89.4) |
99 | 0.55 (0.65) |
4.00 (4.71) |
||||
INHP5-330Eco | 33.0 (35.2) |
99.999 | 0.6 (0.7) |
5.13 (6.05) |
37 | W:2,450 × D:870 × H:1,650 |
1,600 | 60 |
INHP4-570Eco | 57.0 (67.0) |
99.99 | ||||||
INHP3-800Eco | 80.0 (93.6) |
99.9 | 5.49 (6.47) |
|||||
INHP2-1140Eco | 114.0 (134.0) |
99 | 0.55 (0.65) |
6.00 |
*1.Product gas generated amount is based on the raw air temperature 35℃ (humidity 85%R.H). At 20℃ (humidity 60%R.H), it increases by about 10%.
*2.N2 gas generated and raw air amount would change by [coefficient] depending on the raw air conditions. Coefficient = (0.1MPa + raw air pressure) ÷ (0.1MPa + 0.69MPa)
*3. If standard casters (with adjuster feet) are attached, the height would increase by 92mm.
*4.The device specifications are subject to change without notice.
Please wait for a moment until the form is displayed.